HTA-W-DL56
PHYSICAL SPECIFICATION
Construction
Frame material
Pane 1 (CR side)
Air cavity
Pane 2 (LR side)
Pane angle offset
Reveal depth (min.)
Standard openings
Custom sizes
Frame sealing
Viewing clarity
Two independent panes, structurally decoupled
Cold-rolled steel, powder-coated
90 mm (silica gel desiccant filled)
10 mm annealed float glass
12 mm laminated safety glass
3° – 7° (adjustable during install)
300 mm wall construction required
900 × 600 mm to 1800 × 1200 mm
Yes
Dual-layer neoprene gasket, continuous bead
High-transmission low-iron glass option
ACOUSTIC PERFORMANCE
STC rating
Rw (weighted)
Worst-case frequency
Test standard
52 – 56 dB
51 dB (ISO 717-1)
~160 Hz (coincidence dip)
ASTM E90 / ISO 10140-2
INSTALLATION REQUIREMENTS
Wall build-up minimum
Structural lintel
Vibration isolation
Conditioned cavity
300 mm — double-leaf masonry or stud
Required — engineer to specify
Neoprene pad at all bearing points
Recommended — prevents condensation
Installation note: The pane angle offset is the single most important installation variable. Eliminating parallel glass surfaces adds 4–6 dB of flutter-echo rejection across mid frequencies. Even a 3° offset is highly effective.