TRIPLE-GLAZED STUDIO WINDOW

 

 

 

 

 

 

 

 

 

 

 

 

HTA-W-TG62

PHYSICAL SPECIFICATION

Construction

Frame material

Pane 1

Cavity 1

Pane 2 (centre)

Cavity 2

Pane 3

Total reveal depth

Desiccant

Perimeter seal

Custom sizes

3 panes-outer pair decoupled, centre floated

Structural steel hotdip galvanised+powdercoat

10 mm annealed float glass

60 mm

12 mm laminated, mass-loaded PVB interlayer

80 mm

14 mm laminated safety glass

400 mm minimum

Molecular sieve in all cavities

Triple neoprene – continuous no-break

900 × 600 mm to 2000 × 1200 mm

 

ACOUSTIC PERFORMANCE

STC rating

Rw (weighted)

Rw+Ctr (traffic)

Test standard

58 – 62 dB

60 dB (ISO 717-1)

57 dB

ISO 10140-2, field verified

 

RECOMMENDED APPLICATIONS

Mastering studios

Broadcast control

Recording / tracking

Home studios

Yes — primary specification

Yes

Yes (where NC-15 or lower required)

Over-specified — consider HTA-W-DL56

 

Installation note: Specify alongside a floating floor and independent structural wall system to fully realise the isolation potential. An STC 62 window becomes the weak link if flanking paths through the structure are not addressed.